All-Fiber OTDR 850/1300nm, 24/25 dB, 1310/1550nm, 32/30 dB
Product DescriptionAll-Fiber OTDR
Combining singlemode and multimode capabilities for enterprise, campus and access networks, this model offers the 850, 1300, 1310 and 1550 nm wavelengths, with respective dynamic ranges of 24, 25, 32 and 30 dB.
Applications
Easy Location and Characterization of Events
EXFO's AXS-110 All-Fiber OTDR helps you boost test productivity for inside-plant applications. Its exceptional 0.8 m event dead zone enables you to easily locate and characterize all events between the transmitter and the central office’s fiber, access and FTTH network applications, where events are usually closely spaced.
Multimode and Singlemode Flexibility
The AXS-110 combines singlemode and multimode functionalities, ideal for premises, private and enterprise network testing. Test multimode fiber within premises, or single-mode fiber between premises—all with a single OTDR unit—and maximize your return on investment.
End-to-End PON Characterization
The AXS-110 lets you test through high-port-count splitters—even 1 x 64 splitters—perfect for passive optical network (PON) testing, delivering these key advantages:
Perfect tool for FTTx contractors and tier-2 certification of premises networks
Pass/fail features that comply with industry standards such as TIA 568c and IEEE 802.3ah
Highest dynamic range of the industry for a handheld OTDR
Power meter option, for crosschecking the total loss using the built-in OTDR laser in continuous source mode
All options for the AXS-110 OTDR line. Please inform us of the specific model and options when getting a quote.

Technical Specifications a
Wavelengths (nm) 850/1300/1310/1490/1550/1625
Dynamic range b (dB) 24/25/37/33/35/37
Pulse width (ns) Multimode: 5, 10, 30, 100, 275, 1000
Single-mode: 5, 10, 30, 100, 275, 1000, 2500, 10 000
Event dead zone c (m) 0.8
Attenuation dead zone c (m) 3.5/4.5/4/4.5/4.5/4.5
Linearity (dB/dB) ±0.03
Loss threshold (dB) 0.01
Loss resolution (dB) 0.01
Sampling resolution (m) Multimode: 0.08 to 2.5; singlemode: 0.08 to 5.0
Sampling points Up to 64 000
Distance uncertainty d (m) ±(0.75 + 0.0025 % x distance + sampling resolution)
Distance range (km) Multimode: 0.1 to 40; singlemode: 0.65 to 260
Typical real-time refresh (Hz) 4
Memory capacity 500 traces
Measurement time User-defined
Stable source output power e (dBm) Multimode: –1.5; singlemode: –7.5
Visual fault locator (optional) Laser, 650 nm ± 10 nm
CW typical Pout of 1.4 mW open beam
a All specifications valid at 23 °C ± 2 °C (73.4 °F ± 3.6 °F) with an FC/PC connector, unless otherwise specified.
b. Typical dynamic range with longest pulse and three-minute averaging at SNR = 1. Multimode dynamic range is specified
for 62.5 μm fiber; a 3 dB reduction is seen when testing 50 μm fiber. AXS-11-12CD-23B is 24/25/32/30.
c. Typical dead zone for multimode reflectance below –35 dB and single-mode reflectance below –45 dB, using shortest pulse.
d. Does not include uncertainty due to fiber index.
e. Typical output power is given at 1300 nm for multimode output and 1550 nm for single-mode output.
f. At 23 ºC ± 1 ºC, 1550 nm and with FC connector. With OTDR in idle mode, battery operated.
g. For ±0.05 dB, from 18 ºC to 28 ºC.
General Specifications
Size (H x W x D) 250 mm x 125 mm x 75 mm (9 7/8 in x 4 15/16 in x 3 in)
Weight 1 kg (2.2 lb)
Temperature operating –18 °C to 50 °C (14 °F to 122 °F)
storage –40 °C to 70 °C (–40 °F to 158 °F)
Relative humidity 0 % to 95 % non-condensing
Power Li-ion batteries; 8 hours of continuous operation as per
Bellcore TR-NWT-001138
Warranty (years) 1